I thought that I corrected for different ranges of pramp,
pulse and threshold DACs
between ABCD and ABC but I didn't so the measuerments
are taken at somewhat
strange values of charges and preamp currents.
* Preamp was set to DAC = 6 (150uA)
* Threshold scans were done at different charges (strobe
delya was optimized
but same value was used for all the
charges)
* Vcc = 3.5V ,Vdd = 4V
Currents measured at Preamp DAC =
11: Ianalogue = 0.39A and Idig = 0.16A
Here are some plots:
An example of threshold scan:
Example of response:
Gain at 0.93fC accross the hybrid:
Noise at 0.93fC across the hybrid:
50% points acros the hybrid:
Threshold Spreads for Chip 0 at 0.93fC:
Average gain for chip 0 is 143.5 units/fC and average
RMS from the above plots is
2.1. The threhold spread is then 0.015fC (at 0.93fC).